this post was submitted on 23 Nov 2025
189 points (92.0% liked)

Mildly Infuriating

42908 readers
1036 users here now

Home to all things "Mildly Infuriating" Not infuriating, not enraging. Mildly Infuriating. All posts should reflect that. Please post actually infuriating posts to !actually_infuriating@lemmy.world

I want my day mildly ruined, not completely ruined. Please remember to refrain from reposting old content. If you post a post from reddit it is good practice to include a link and credit the OP. I'm not about stealing content!

It's just good to get something in this website for casual viewing whilst refreshing original content is added overtime.


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means: -No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...


7. Content should match the theme of this community.


-Content should be Mildly infuriating. If your post better fits !Actually_Infuriating put it there.

-The Community !actuallyinfuriating has been born so that's where you should post the big stuff.

...


8. Reposting of Reddit content is permitted, try to credit the OC.


-Please consider crediting the OC when reposting content. A name of the user or a link to the original post is sufficient.

...

...


Also check out:

Partnered Communities:

1.Lemmy Review

2.Lemmy Be Wholesome

3.Lemmy Shitpost

4.No Stupid Questions

5.You Should Know

6.Credible Defense


Reach out to LillianVS for inclusion on the sidebar.

All communities included on the sidebar are to be made in compliance with the instance rules.

founded 2 years ago
MODERATORS
 

People who joke about legos haven't stepped on this bad boy

you are viewing a single comment's thread
view the rest of the comments
[–] Devial@discuss.online 18 points 10 hours ago* (last edited 10 hours ago) (2 children)

No, because the rest of the world isn't America.

Those ring circuits WERE up to UK standard, and perfectly safe when they were constructed, and nowadays are either still covered by the standard, or grandfathered in, meaning at minimum in existing buildings, they still in fact are up to UK standard.

The reason other counties don't use ring circuits isn't because they're less safe or inherently worse in any way, which the term "substandard" clearly implies. It's because they're less convenient. It's easier and more convenient to make and use, and easier in terms of individual steps, to make safe seperate fused circuits instead of a ring circuit.

The reason the UK used ring circuits was because they use much less copper conduit, and given the massive ~~copper~~ everything shortage in the UK during and after WWII, the convenience of modern circuits simply wasn't worth it.

[–] Horsecook@sh.itjust.works 1 points 3 hours ago

The reason other counties don’t use ring circuits isn’t because they’re less safe or inherently worse in any way, which the term “substandard” clearly implies.

Yes. That is the reason.

If a ring circuit suffers a break in the live wire anywhere along its length, it fails dangerous. It will appear to be functioning properly right up until the wiring in the wall catches fire.

The only way that ring circuits could be considered somewhat safe is if they were clearly labeled and regularly tested for continuity.