[–] stoicmaverick@lemmy.world 50 points 4 weeks ago (37 children)

Okay, who gets to be the lucky one to calculate the amount of time that thing could heat sink a pegged, modern, 120w TDP CPU before it throttles at 100C? I'll give you a sticker.

[–] KSPAtlas@sopuli.xyz 56 points 4 weeks ago (14 children)

Let's assume the dimensions of the copper block are 40mm40mm160mm (I'm not taking the heat spreader into account here)

That results in a volume of 256000mm3, or 256cm3

Copper (at 20C) has a density of 8.935 g/cm3, so that's roughly 2.28736kg of copper

Copper has a specific heat capacity of 384.603 J/(kg K)

Using E=cm∆t, we can figure out that it would take ≈ 70378J of energy to heat the copper block to 100C, starting at 20C

With a TDP od 120W, that means it would take 586 seconds to heat the block to 100C, or 9m46s

This is probably way off but I was bored

[–] Rugnjr@lemmy.blahaj.zone 1 points 4 weeks ago

This doesn't seem to account for convection, which is presumably the entire point of a heat sink?