Hi,

I am thinking about the best way to transmit 5 single ended signals from one board to another as well as ground and 2 power rails. I was thinking cat5e cable with a standard rj45 plug but as cat5e is twisted pair I'm concerned about crosstalk.

The cable between the two boards would be a maximum of 50cm. 3 of the signals are addresses for a multiplexer that would change at a maximum speed of 2ms per change. One of the other signals is a 20khz pwm signal. The final signal is a zc detector for mains so max Freq of 100/120hz.

There may be high current switches at ac line frequency (50/60hz) near by.

Would single ended transmission with cat5e cable be okay for this or would I need differential signalling? If I need differential signalling, what sort of cable/connector could I use?

Any help is appreciated

Thanks

you are viewing a single comment's thread
view the rest of the comments
[–] TelepathicWalrus@lemmy.world 1 points 5 days ago

Thank you for your response. I was hoping to run the power (3.3v and 24v) through the same cat5e cable. They wouldn't be high current, probably 100ma max. Do you think this would be ok too?